{"product_id":"grundfos-jp-4-54-pm1-bbvp-self-priming-pressure-pump","title":"Grundfos JP 4-54 PM1 BBVP Self Priming Pressure Pump","description":"\u003cp class=\"isSelectedEnd\" id=\"c1-id-374\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-375\"\u003eThe Grundfos JP 4-54 PM1 is a complete booster pump system designed for domestic and garden water supply applications. It combines a self-priming, single-stage centrifugal JP pump with a PM1 pressure manager to provide automatic start and stop according to water demand and consistent water pressure.\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"isSelectedEnd\" id=\"c1-id-376\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-377\"\u003eThe self-priming pump can lift water from below the inlet level and handle a mixture of air and water during priming, with a suction lift of up to 8m. Dry-running and anti-cycling protection help protect the pump from damage and unnecessary cycling.\u003c\/span\u003e\u003c\/p\u003e\u003ch3 id=\"c1-id-378\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-379\"\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\u003cul id=\"c1-id-380\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003cli id=\"c1-id-381\"\u003e\u003cspan id=\"c1-id-382\"\u003eComplete booster pump system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-383\"\u003e\u003cspan id=\"c1-id-384\"\u003eSelf-priming, single-stage centrifugal pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-385\"\u003e\u003cspan id=\"c1-id-386\"\u003eAutomatic start and stop according to water demand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-387\"\u003e\u003cspan id=\"c1-id-388\"\u003ePM1 pressure manager with 1.5 bar start pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-389\"\u003e\u003cspan id=\"c1-id-390\"\u003eDry-running protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-391\"\u003e\u003cspan id=\"c1-id-392\"\u003eAnti-cycling protection with leakage detection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-393\"\u003e\u003cspan id=\"c1-id-394\"\u003eIntegrated non-return valve for backflow prevention\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-395\"\u003e\u003cspan id=\"c1-id-396\"\u003eBuilt-in thermal motor protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-397\"\u003e\u003cspan id=\"c1-id-398\"\u003eRobust construction using corrosion-free materials\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-399\"\u003e\u003cspan id=\"c1-id-400\"\u003eSelf-priming capability with suction lift up to 8m\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-401\"\u003e\u003cspan id=\"c1-id-402\"\u003eAir-cooled motor with sealed, greased-for-life ball bearings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-403\"\u003e\u003cspan id=\"c1-id-404\"\u003eSuitable for domestic and garden applications\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 id=\"c1-id-405\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-406\"\u003eSpecifications\u003c\/span\u003e\u003c\/h3\u003e\u003cul id=\"c1-id-407\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003cli id=\"c1-id-408\"\u003e\n\u003cstrong id=\"c1-id-409\"\u003e\u003cspan id=\"c1-id-410\"\u003eMotor \/ Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-411\"\u003e 1130W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-412\"\u003e\n\u003cstrong id=\"c1-id-413\"\u003e\u003cspan id=\"c1-id-414\"\u003eMaximum Flow:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-415\"\u003e 66 L\/min\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-416\"\u003e\n\u003cstrong id=\"c1-id-417\"\u003e\u003cspan id=\"c1-id-418\"\u003eMaximum Head:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-419\"\u003e 46m\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-420\"\u003e\n\u003cstrong id=\"c1-id-421\"\u003e\u003cspan id=\"c1-id-422\"\u003ePressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-423\"\u003e 460kPa\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-424\"\u003e\n\u003cstrong id=\"c1-id-425\"\u003e\u003cspan id=\"c1-id-426\"\u003eInlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-427\"\u003e 1\" female \/ 25mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-428\"\u003e\n\u003cstrong id=\"c1-id-429\"\u003e\u003cspan id=\"c1-id-430\"\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-431\"\u003e 1\" male \/ 25mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-432\"\u003e\n\u003cstrong id=\"c1-id-433\"\u003e\u003cspan id=\"c1-id-434\"\u003eImpeller:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-435\"\u003e Composite\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-436\"\u003e\n\u003cstrong id=\"c1-id-437\"\u003e\u003cspan id=\"c1-id-438\"\u003eStart Pressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-439\"\u003e PM1 – 1.5 bar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-440\"\u003e\n\u003cstrong id=\"c1-id-441\"\u003e\u003cspan id=\"c1-id-442\"\u003eSuction Lift:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-443\"\u003e Maximum 8m\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-444\"\u003e\n\u003cstrong id=\"c1-id-445\"\u003e\u003cspan id=\"c1-id-446\"\u003eMaximum System Pressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-447\"\u003e 6 bar\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 id=\"c1-id-448\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-449\"\u003eOperating Specifications\u003c\/span\u003e\u003c\/h3\u003e\u003cul id=\"c1-id-450\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003cli id=\"c1-id-451\"\u003e\n\u003cstrong id=\"c1-id-452\"\u003e\u003cspan id=\"c1-id-453\"\u003eAmbient Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-454\"\u003e 0°C to +40°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-455\"\u003e\n\u003cstrong id=\"c1-id-456\"\u003e\u003cspan id=\"c1-id-457\"\u003eLiquid Temperature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-458\"\u003e 0°C to +40°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-459\"\u003e\n\u003cstrong id=\"c1-id-460\"\u003e\u003cspan id=\"c1-id-461\"\u003eSupply Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-462\"\u003e 1 x 230V, 50Hz \/ 1 x 115V, 60Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-463\"\u003e\n\u003cstrong id=\"c1-id-464\"\u003e\u003cspan id=\"c1-id-465\"\u003eEnclosure Class:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-466\"\u003e IP44 – suitable for covered installation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-467\"\u003e\n\u003cstrong id=\"c1-id-468\"\u003e\u003cspan id=\"c1-id-469\"\u003eCable:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-470\"\u003e 1.5m with plug\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 id=\"c1-id-471\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-472\"\u003eComponents\u003c\/span\u003e\u003c\/h3\u003e\u003cul id=\"c1-id-473\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003cli id=\"c1-id-474\"\u003e\u003cspan id=\"c1-id-475\"\u003eSelf-priming Grundfos JP pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-476\"\u003e\u003cspan id=\"c1-id-477\"\u003ePM1 pressure manager, wired to the pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-478\"\u003e\u003cspan id=\"c1-id-479\"\u003eAutomatic start\/stop with 1.5 bar start pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-480\"\u003e\u003cspan id=\"c1-id-481\"\u003eDry-running protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-482\"\u003e\u003cspan id=\"c1-id-483\"\u003eAnti-cycling protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-484\"\u003e\u003cspan id=\"c1-id-485\"\u003eIntegrated non-return valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli id=\"c1-id-486\"\u003e\u003cspan id=\"c1-id-487\"\u003e1.5m cable with plug\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 id=\"c1-id-488\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-489\"\u003eProtection Features\u003c\/span\u003e\u003c\/h3\u003e\u003cp class=\"isSelectedEnd\" id=\"c1-id-490\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-491\"\u003eThe PM1 pressure manager automatically starts the pump when pressure drops below 1.5 bar and keeps the pump running while there is water flow. Dry-running protection automatically stops the pump if no water is detected. The anti-cycling function stops the pump if a minor leak or partially open tap causes repeated cycling, with an alarm indicated when cycling occurs.\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"isSelectedEnd\" id=\"c1-id-492\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-493\"\u003eThe pump also features built-in thermal protection to stop the motor if it overheats.\u003c\/span\u003e\u003c\/p\u003e\u003cp class=\"isSelectedEnd\" id=\"c1-id-494\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cstrong id=\"c1-id-495\"\u003e\u003cspan id=\"c1-id-496\"\u003eFormerly known as the JPC 4-54 PM1.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3 id=\"c1-id-497\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\u003cspan id=\"c1-id-498\"\u003eProduct Details\u003c\/span\u003e\u003c\/h3\u003e\u003cul id=\"c1-id-499\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003cli id=\"c1-id-500\"\u003e\n\u003cstrong id=\"c1-id-501\"\u003e\u003cspan id=\"c1-id-502\"\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-503\"\u003e JP 4-54 PM1 BBVP\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-504\"\u003e\n\u003cstrong id=\"c1-id-505\"\u003e\u003cspan id=\"c1-id-506\"\u003eCode:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-507\"\u003e 99463900\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli id=\"c1-id-508\"\u003e\n\u003cstrong id=\"c1-id-509\"\u003e\u003cspan id=\"c1-id-510\"\u003eWarranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan id=\"c1-id-511\"\u003e 2 years\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":49295254880564,"sku":"PU122A1","price":798.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0745\/5814\/4820\/files\/d42f68e1-862a-4a06-96f9-8a83e2de5fba.png?v=1789962335","url":"https:\/\/shop.lincolnrural.com.au\/products\/grundfos-jp-4-54-pm1-bbvp-self-priming-pressure-pump","provider":"Lincoln Rural","version":"1.0","type":"link"}